Karelia Premium H20 test results
Table 4 of the test report dated 17 February 2025.
- Characteristic bending moment Mₖ
- 11.29 kN·m
- Shear force Vk
- 27.74 kN
- Bearing resistance Rb,k
- 52.05 kN
- Bending stiffness EI
- 459.9 kN·m²
EN 13377:2002 standard values
Class P20, Table 1.
- Characteristic bending moment Mₖ
- 10.9 kN·m
- Shear force Vk
- 23.9 kN
- Bearing resistance Rb,k
- 47.8 kN
- Bending stiffness EI
- 450 kN·m²
H20 beam dimensions and weight
- Beam lengths
- 1,500–6,000 mm
- Beam height
- 200 mm
- Flange width
- 80 mm
- Flange thickness
- 40 mm
- Plywood thickness
- 24 mm
- Plywood web width
- 120 mm
- Joint insertion depth
- 13 mm
- Flange shoulder width
- 28 mm
- Weight per metre
- 5.2 kg per linear metre
- Product standard
- EN 13377:2002
- Additional standards
- GOST 34329-2017; GOST R ISO 9001-2015
Materials and reference standards
24 mm FK birch plywood: DIN EN 636:2015-05. Softwood flanges: DIN EN 14080:2013-09.
EN 13377:2002 specifies EN 301 Type I as the requirement for beam joint adhesives.
We use one-component polyurethane adhesives, PURBOND HB S109 and KLEIBERIT, to bond the plywood web to the flanges.
KLEIBERIT 303.2, a PVAc dispersion adhesive, is used separately for longitudinal finger-jointing of flange timber. Adhesives and their applications. EN 13377:2002 applies to the finished beam.
We produce the flanges using a 2-ex-log sawing pattern from logs 12–16 cm in diameter.
For beams up to and including 3.90 m long, each flange may have no more than one longitudinal joint. For beams longer than 3.90 m, each flange may have no more than two longitudinal joints.